<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE ArticleSet PUBLIC "-//NLM//DTD PubMed 2.7//EN" "https://dtd.nlm.nih.gov/ncbi/pubmed/in/PubMed.dtd">
<ArticleSet>
<Article>
<Journal>
				<PublisherName>پژوهشگاه  بین المللی زلزله شناسی و مهندسی زلزله</PublisherName>
				<JournalTitle>فصلنامه علوم و مهندسی زلزله</JournalTitle>
				<Issn>2476-6097</Issn>
				<Volume>2</Volume>
				<Issue>3</Issue>
				<PubDate PubStatus="epublish">
					<Year>2015</Year>
					<Month>09</Month>
					<Day>23</Day>
				</PubDate>
			</Journal>
<ArticleTitle>Soil-Structure System Identification with Ambient Vibration Tests (A Case-Study on a Surface Pier of Kermanshah Urban Railroad)</ArticleTitle>
<VernacularTitle>شناسایی سیستم دینامیکی خاک–سازه با استفاده از آزمایش ارتعاش محیطی (مطالعه موردی: پایه مسیر روزمینی قطار شهری کرمانشاه)</VernacularTitle>
			<FirstPage>1</FirstPage>
			<LastPage>13</LastPage>
			<ELocationID EIdType="pii">240271</ELocationID>
			
			
			<Language>FA</Language>
<AuthorList>
<Author>
					<FirstName>مجید</FirstName>
					<LastName>لامعی</LastName>
<Affiliation>دانشگاه رازی</Affiliation>

</Author>
<Author>
					<FirstName>ایمان</FirstName>
					<LastName>عشایری</LastName>
<Affiliation>گروه مهندسی عمران، دانشگاه رازی</Affiliation>
<Identifier Source="ORCID">0000-0002-7312-881X</Identifier>

</Author>
<Author>
					<FirstName>مهنوش</FirstName>
					<LastName>بیگلری</LastName>
<Affiliation>گروه مهندسی عمران،  دانشگاه رازی</Affiliation>

</Author>
<Author>
					<FirstName>محمدامین</FirstName>
					<LastName>کدیور</LastName>
<Affiliation>دانشگاه آزاد اسلامی واحد علوم و تحقیقات اصفهان</Affiliation>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2016</Year>
					<Month>02</Month>
					<Day>13</Day>
				</PubDate>
			</History>
		<Abstract>During an earthquake, the dynamic response of a structure located on a soil deposit could be very complex compared with the analysis of the same structure on bedrock due to the interactions between the soil and the structure. This phenomenon is technically termed as Soil-Structure Interaction (SSI) effects in literature. Most of what is currently known about soil-structure interaction (SSI) is based on theoretical and mathematical models. Therefore, it is necessary to investigate the structure treatments when they response to the ground strong motions transferred by SSI. In this regard, in an experimental field, the present study investigated the SSI effects on structure, evaluating the natural frequencies and damping of a pile-group-supported pier of Kermanshah’s LRT. The frequencies and damping evaluations were performed through ambient vibration test results and system identification procedures. The purpose of system identification is to evaluate unknown properties of a system, using known inputs and outputs. There are two principal system identification procedures to build mathematical models of dynamical systems from measured data: (a) non-parametric and (b) parametric procedures. Non-parametric procedures evaluate complex-valued transmissibility functions from the input and output recordings without fitting an underlying model. Accordingly, Fourier Transform (FT), response square of transfer function, peak picking and four spectra are considered as non-parametric procedures. On the other hand, parametric procedures develop numerical models of transfer functions. More precisely, in these procedures, a mathematical model with several parameters is defined first. The considered parameters are featured with specific values determined by experimental results. Then, the system’s input-output function is obtained using this described model. The studied pier was fully instrumented with two SARA and a CEM seismometers. The seismometers recorded signals of two horizontal and a vertical components that were digitally recorded at 200 Hz sampling rate. In general, measure of SSI effects was then obtained by comparing the flexible-base and fixed-base parameters to calculate the two most important effects of SSI, period lengthening and foundation damping. SAP 2000 was used to create a finite element model of the whole structure and the accuracy of the model was tested using recorded data from ambient vibration at the structure site. In summary, the current study indicates that all the utilized system identification methods are appropriate in determining the dynamic characteristics of the structure in fixed condition. In addition, it was demonstrated that peak picking and four spectral methods did not have appropriate function in investigating the interaction. However, these two procedures have appropriate function in determining the dynamic characteristics of the structure in fixed condition. As Figure (1) shows, the diagram of the period lengthening obtained from parametric method with the ratio of the structure-to-soil stiffness for the pier is approximately consistent with system identification analyses performed for the 57 sites in Stewart et al. [1]. Accordingly, inertial interaction effects were generally observed to be small for 1/σ &lt; 0.1 and for practical purposes could be neglected in such cases. &lt;br /&gt;&lt;span style=&quot;left: 106.4px; top: 618.698px; font-size: 16.8px; font-family: serif; transform: scaleX(1.04602);&quot;&gt;Reference1.Stewart, J.P. and Fenves, G.L., and Seed, R.B. (1999) Seismic soil-structure interaction in buildings. I: Analytical aspects. Journal of Geotechnical and Geoenv. Engineering, ASCE, 125(1), 26-37.&lt;/span&gt;</Abstract>
			<OtherAbstract Language="FA">با توجه به اهمیت اندرکنش خاک-سازه در انتقال حرکت‌های نیرومند زمین به سازه و پاسخ سازه به این حرکت‌ها،ضمن توجه به این که مدل‌های ریاضی و تئوری بر پایه فرضیات خاصی مطرح می‌شوند، لزوم شناخت رفتار سازه‌ها به همان صورتی که ساخته می‌شوند، احساس می‌شود. در این مقاله، جهت تعیین آثار اندرکنش خاک-سازه در یک تحقیق میدانی، یک مورد از پایه‌های مسیر روزمینی قطار شهری کرمانشاه که پی آن به صورت گروه شمع می‌باشد، با بررسی فرکانس‌های طبیعی و میرایی با استفاده از نتایج آزمایش ارتعاش محیطی و روش‌های مختلف شناسایی سیستم سازه‌ها مورد مطالعه قرار می‌گیرد. بر این اساس خصوصیات دینامیکی سازه‌ی مورد نظر در دو حالت پایه گیردار و پایه انعطاف‌پذیر ارزیابی می‌شوند،و سپس نتایج به دست‌آمده از روش‌های مختلف شناسایی سیستم با نتایج حاصل از مدل المان محدود مقایسه می‌گردند. در مجموع، پژوهش حاضر نشان میدهد که در تمامی روشهای شناسایی مقادیر فرکانس‌های طبیعی انطباق مناسبی با هم دارند.</OtherAbstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">شناسایی سیستم</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">اندرکنش خاک-سازه</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">فرکانس طبیعی</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">ارتعاشات محیطی</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">گروه شمع</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://www.bese.ir/article_240271_ec550efe11cb39c87646f0d0d17a010e.pdf</ArchiveCopySource>
</Article>

<Article>
<Journal>
				<PublisherName>پژوهشگاه  بین المللی زلزله شناسی و مهندسی زلزله</PublisherName>
				<JournalTitle>فصلنامه علوم و مهندسی زلزله</JournalTitle>
				<Issn>2476-6097</Issn>
				<Volume>2</Volume>
				<Issue>3</Issue>
				<PubDate PubStatus="epublish">
					<Year>2015</Year>
					<Month>09</Month>
					<Day>23</Day>
				</PubDate>
			</Journal>
<ArticleTitle>Tehran Subway Tunnel Effect on the Seismic Response of the Ground Surface with Linear Soil Behavior: An Experimental and Numerical Study</ArticleTitle>
<VernacularTitle>تأثیر تونل مترو شهر تهران بر پاسخ لرزه‌ای سطح زمین در محدوده رفتار خطی خاک: مطالعه آزمایشگاهی و عددی</VernacularTitle>
			<FirstPage>15</FirstPage>
			<LastPage>36</LastPage>
			<ELocationID EIdType="pii">240272</ELocationID>
			
			
			<Language>FA</Language>
<AuthorList>
<Author>
					<FirstName>محمدحسن</FirstName>
					<LastName>بازیار</LastName>
<Affiliation>دانشکده عمران، دانشگاه علم و صنعت ایران</Affiliation>

</Author>
<Author>
					<FirstName>عباس</FirstName>
					<LastName>قلندرزاده</LastName>
<Affiliation>دانشکده عمران، پردیس دانشکده‌های فنی دانشگاه تهران</Affiliation>
<Identifier Source="ORCID">0000-0001-9939-7842</Identifier>

</Author>
<Author>
					<FirstName>مسعود</FirstName>
					<LastName>رابطی‌مقدم</LastName>
<Affiliation>دانشگاه علم و صنعت ایران</Affiliation>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2016</Year>
					<Month>02</Month>
					<Day>13</Day>
				</PubDate>
			</History>
		<Abstract>In the current study, a series of 1 g shaking table tests was performed to study the Tehran subway tunnel effect on the ground surface acceleration response. Two reduced-scale 1 g shaking table models, designated as FF and SF, were constructed in 1/32 scale. The FF was constructed to study the seismic response of the soil layer in free field condition, while the SF model includes a subway tunnel to study its effect on the acceleration response of nearby ground. In prototype scale, the subway tunnel with 8 m diameter and 0.35 m thickness was embedded in a soil layer with 32 m thickness. The soil was dense sand with 70% of relative density. The models were constructed in a rigid box made from Plexi-glass with dimensions of 178*80*120 cm (L.H.W.). Lateral boundaries of the models were covered with conventional foam in order to reduce the lateral boundary effect on the seismic response of the soil layer. The constructed SF model is depicted in Figure (1a). The accelerometers and LVDT transducers installed in the models to record the acceleration in the soil and settlement at model surface are illustrated in Figure (1b). &lt;br /&gt;The experimental study revealed that the tunnel does not affect the incident waves with dimensionless period (λ/D) larger than 10. Previous numerical studies [1-2] also demonstrated that an underground tunnel does not affect the free field response at λ/D greater than 10. Up to now, this finding has not been demonstrated by any experimental research. However, the physical modeling performed here is suffered from some limitations regarding the applied frequencies. Therefore, a numerical model was developed based on the results of the shaking table tests, and the effect of the tunnel on the excitations with higher frequency ranges was investigated. Besides, the effect of different parameters such as shear wave velocity of the soil, flexibility ratio and depth of the tunnel on the acceleration at the ground surface was numerically determined. Figure (2) shows the numerical model of the SF model in prototype scale. &lt;br /&gt;Six real earthquake motions that were matched to the response spectrum of ground type I in Standard 2800 were used in the parametric analyses. PGA of the motions was scaled to 0.35 g. The push of the amplification during the analyses were considered as the maximum response and depicted as amplification pattern at the ground surface. Amplification pattern at the ground surface for a tunnel at h/a=1.5 in soils with different shear wave velocities (VS) is depicted in Figure (3). As presented, the maximum amplification occurred at X/a = 1.5 for all Vs. Moreover, as the shear wave velocity increases, the amplification ratio decreases. The study revealed that the amount of the amplification on the ground surface depends on the tunnel depth and shear wave velocity of the soil. The maximum amplifications at the ground surface was equal to 5, 8 and 10 percent for the tunnel depth rations of 1.5, 2 and 3, respectively, in a soil medium with 175 m/s of the shear wave velocity. The effect of tunnel depth on the amplification pattern was investigated in the parametric study. It was concluded that as the tunnel depth increases, the amplification ratio decreases. The tunnel depth affects the location of the maximum amplifications. As the tunnel depth increases, the location of the maximum amplification gets away from the tunnel center and occurs at longer distance from the tunnel center. &lt;br /&gt;The effect of the Tehran subway tunnel on the response spectrum at the ground surface in different soil for different ratios of the tunnel depth was investigated. It was concluded that the subway tunnel in soils with different shear wave velocity affects the different ranges of the periods. A subway tunnel with 8 m diameter influences the seismic response of the buildings with the period lower than 0.4 sec or the buildings smaller than 10 m. It means that the tunnel has an adverse effect on the short buildings. &lt;br /&gt;References 1. Yiouta-Mitra, P., Kouretzis, G., Bouckovalas, G., and Sofianos, A. (2007) Effect of underground structures in earthquake resistant design of surface structures. Dynamic Response and Soil Properties, Geo-Denver: New Peaksin Geotechnics. 2. Alielahi, H., Kamalian, M., and Adampira, M (2015) Seismic ground amplification by unlined tunnels subjected to vertically propagating SV and P waves using BEM. Soil Dynamics and Earthquake Engineering, 71, 63-79.</Abstract>
			<OtherAbstract Language="FA">در مقاله حاضر، با انجام آزمایش‌های میز لرزه و روش عددی اعتبارسنجی شده با نتایج آزمایش‌ها، به بررسی اثرات حضور تونل مترو شهر تهران بر پاسخ لرزه‌ای سطح زمین در محدوده رفتار خطی خاک پرداخته شده است. تأثیر تونل مترو بر الگوی بزرگنمایی شتاب و همچنین اثر آن بر طیف پاسخ شتاب در سطح زمین مورد مطالعه قرار گرفته است. اثر پارامترهای عمق تونل و سرعت موج برشی محیط بر میزان بزرگنمایی‌ها برای امواج واقعی زلزله مورد مطالعه پارامتری قرار گرفته است. از مطالعات چنین نتیجه‌گیری شد که میزان حداکثر بزرگنمایی تابع عمق تونل و سرعت موج برشی محیط بوده که بیشینه آن برای نسبت عمقهای 1/5، 2 و 3 به ترتیب برابر با 10، 8 و 5 درصد برای خاکی با سرعت مو ج برشی 175 متر بر ثانیه بود. همچنین نتیجه‌گیری شد که حضور تونل مترو در خاک‌های مختلف، محدوده فرکانسی متفاوتی از سازه‌ها را تحت تأثیر قرار می‌دهد به‌طوری‌که سازه‌های با محدوده پریودی بالاتر از 0/4 ثانیه تحت تأثیر حضور تونل مترو قرار نمی‌گیرند.</OtherAbstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">تونل مترو</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">شهر تهران</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">بزرگنمایی لرزه‌ای</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">سطح زمین</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">مدلسازی فیزیکی</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">مدلسازی عددی</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://www.bese.ir/article_240272_0f44a35a40ac7fad89e6e4c9f1981725.pdf</ArchiveCopySource>
</Article>

<Article>
<Journal>
				<PublisherName>پژوهشگاه  بین المللی زلزله شناسی و مهندسی زلزله</PublisherName>
				<JournalTitle>فصلنامه علوم و مهندسی زلزله</JournalTitle>
				<Issn>2476-6097</Issn>
				<Volume>2</Volume>
				<Issue>3</Issue>
				<PubDate PubStatus="epublish">
					<Year>2015</Year>
					<Month>09</Month>
					<Day>23</Day>
				</PubDate>
			</Journal>
<ArticleTitle>Seismic Bearing Capacity Factor of Unit Weight  Under Inclined Load Using the Kötter Equation</ArticleTitle>
<VernacularTitle>تعیین ضریب باربری لرزه‌ای پی‌های سطحی تحت بار مایل با استفاده از معادله‌ی کوتر</VernacularTitle>
			<FirstPage>37</FirstPage>
			<LastPage>49</LastPage>
			<ELocationID EIdType="pii">240273</ELocationID>
			
			
			<Language>FA</Language>
<AuthorList>
<Author>
					<FirstName>مرتضی</FirstName>
					<LastName>جیریایی شراهی</LastName>
<Affiliation>دانشگاه صنعتی قم، گروه مهندسی عمران</Affiliation>

</Author>
<Author>
					<FirstName>سید مجتبی</FirstName>
					<LastName>موسوی اوریمی</LastName>
<Affiliation>دانشگاه صنعتی قم، گروه مهندسی عمران</Affiliation>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2016</Year>
					<Month>02</Month>
					<Day>13</Day>
				</PubDate>
			</History>
		<Abstract>Experimental and theoretical investigations indicate that the seismic bearing capacity of foundations is affected by earthquake excitation. In the present study, an analytical procedure is presented to obtain the seismic bearing capacity factor of shallow strip footing NγE for a foundation under inclined load on cohesionless soils. The limit equilibrium method with numerical iteration technique is utilized to calculate the seismic bearing capacity factor NγE. In the proposed analysis the Kötter’s equation and a failure surface consisting log-spiral and planar surface are employed. The results indicate that the seismic bearing capacity is reduced due to an increase in horizontal coefficient of earthquake acceleration. Besides, the results are in good agreement with solutions available in the literature.</Abstract>
			<OtherAbstract Language="FA">تعیین ظرفیت باربری پی‌های سطحی در هنگام زلزله یکی از موضوعات مهم ژئوتکنیک لرزه‌ای است. در این تحقیق، با به‌کارگیری روش تعادل حدی، (NγE) معادله‌ی کوتر و روش سعی و خطا، بهینه‌ترین ضریب باربری لرزه‌ای روی خاک غیر چسبنده برای پی سطحی، که علاوه بر بار قائم تحت بار افقی نیز می‌باشد، به‌دست‌آمده است. در این روش، سطح گسیختگی خاک زیر پی، به‌صورت مرکب (صفحه‌ای و اسپیرال لگاریتمی) در نظر گرفته شده است. از مزایای این روش، تعیین سطح گسیختگی متناسب با ویژگی‌های خاک و ضرایب شتاب زلزله است. بر اساس نتایج به‌دست‌آمده از این تحلیل، با افزایش شتاب زلزله و افزایش بار افقی، ضریب باربری لرزه‌ای پی سطحی کاهش می‌یابد. نتایج حاصل از این تحقیق با دیگر نتایج موجود در متون علمی مقایسه شد و در اکثر حالات انطباق خوبی نشان داد.</OtherAbstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">زلزله</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">ضریب باربری لرزه‌ای</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">بار مایل</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">پی‌های سطحی</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">معادله‌ی کوتر</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">تعادل حدی</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://www.bese.ir/article_240273_a3e5ad917c995bc076b2e87bbb7d3009.pdf</ArchiveCopySource>
</Article>

<Article>
<Journal>
				<PublisherName>پژوهشگاه  بین المللی زلزله شناسی و مهندسی زلزله</PublisherName>
				<JournalTitle>فصلنامه علوم و مهندسی زلزله</JournalTitle>
				<Issn>2476-6097</Issn>
				<Volume>2</Volume>
				<Issue>3</Issue>
				<PubDate PubStatus="epublish">
					<Year>2015</Year>
					<Month>09</Month>
					<Day>23</Day>
				</PubDate>
			</Journal>
<ArticleTitle>Nonlinear Seismic Analysis of Pile Groups in  Layered Soils due to Kinematic Interaction Effects</ArticleTitle>
<VernacularTitle>تحلیل لرزه‌‎ای غیرخطی گروه شمع واقع در خاک‌های لایه‌ای ناشی از اثرات اندرکنش کینماتیکی</VernacularTitle>
			<FirstPage>51</FirstPage>
			<LastPage>62</LastPage>
			<ELocationID EIdType="pii">240274</ELocationID>
			
			
			<Language>FA</Language>
<AuthorList>
<Author>
					<FirstName>حسین</FirstName>
					<LastName>تحقیقی</LastName>
<Affiliation>گروه مهندسی عمران، دانشگاه کاشان</Affiliation>

</Author>
<Author>
					<FirstName>مجید</FirstName>
					<LastName>شبخوان</LastName>
<Affiliation>دانشگاه آزاد کاشان</Affiliation>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2016</Year>
					<Month>02</Month>
					<Day>13</Day>
				</PubDate>
			</History>
		<Abstract>During earthquakes, piles undergo stresses due both motion of the superstructure (i.e. inertial interaction) and that of the surrounding soil (i.e. kinematic interaction). In practice, structural engineers commonly take into account stresses induced by the inertial interaction, which is responsible for pile head failure, but they neglect the effects of the kinematic interaction that is responsible for failures along pile’s length in the case of layered soils with highly contrasting mechanical characteristics even in the absence of the superstructure. Thus, the evaluation of kinematic forces developing in piles during earthquakes has been receiving increased interest from the researchers. Numerical methods for the analysis of kinematic soil-pile interaction can be classified into two groups; continuum-based approaches and Winkler methods [1-3]. It has been customary in professional engineering and research practices to assume a linear behaviour for the soil and the pile foundation. However, under strong excitation, the nonlinear behaviour of soil media at the soil-pile interface has a strong influence on the response of the pile foundation. The aim of this study is to investigate the influence of soil nonlinearities on the kinematic interaction forces of pile groups embedded in layered soil deposits during seismic actions. Figure (1) shows the assumed soil-pile group case with 5 by 5 piles embedded in two layer subsoil profile. The pile has been considered as an elastic beam, while the soils have been modelled using the elastic-plastic solid element. The corresponding 3D finite element mesh has been shown in Figure (2). Based on the symmetry, only half of the model is meshed.</Abstract>
			<OtherAbstract Language="FA">با توجه به کاربرد وسیع پی‌های شمعی، ایمنی شمعها در زمان زلزله از اهمیت ویژه‌ای برخوردار است. تحقیقات نشان داده است که علاوه بر نیروی ناشی از روسازه، اثرات اندرکنش کینماتیکی خاک-شمع باعث اعمال تقاضای لرزه‌ای قابل‌توجهی به شمع‌ها در محیط‌های با خاک لایه‌ای می‌شود. در این مقاله از نرم‌افزار اجزاء محدود سه‌بعدی ABAQUS برای تحلیل لرزه‌ای اندرکنش کینماتیکی گروه شمع در خاک‌های لایه‌ای دارای رفتار غیرخطی استفاده شده است. پس از ارزیابی صحت نتایج روش تحلیل عددی تحت بارگذاری‌های استاتیکی و دینامیکی، اثرات اندرکنش کینماتیکی روی رفتار مکانیکی گروه شمع واقع در خاک دو لایه‌ای (لایه‌ی نرم بر روی لایه‌ی سخت) بحث و بررسی می‌گردد. مطالعات پارامتری شامل عوامل مؤثر بر پاسخ سیستم خاک-شمع نشان می‌دهد که نسبت فاصله به قطر شمع، تعداد شمعها درگروه، قطر شمع، نحوه‌ی اتصال شمع به کلاهک و تغییر مشخصات لایه‌های خاک، تأثیر قابل‌ملاحظه‌ای در رفتار گروه شمع در برابر زلزله دارد.</OtherAbstract>
<ArchiveCopySource DocType="pdf">https://www.bese.ir/article_240274_d45c0a8575a0d0b51abdff32705afae2.pdf</ArchiveCopySource>
</Article>

<Article>
<Journal>
				<PublisherName>پژوهشگاه  بین المللی زلزله شناسی و مهندسی زلزله</PublisherName>
				<JournalTitle>فصلنامه علوم و مهندسی زلزله</JournalTitle>
				<Issn>2476-6097</Issn>
				<Volume>2</Volume>
				<Issue>3</Issue>
				<PubDate PubStatus="epublish">
					<Year>2015</Year>
					<Month>09</Month>
					<Day>23</Day>
				</PubDate>
			</Journal>
<ArticleTitle>Role of Seismic Load Characteristics on Permanent Settlement  of Shallow Foundations on Liquefiable Sand</ArticleTitle>
<VernacularTitle>تأثیر مشخصات بار لرزه‌ای بر نشست دائمی پی‌های سطحی مستقر بر ماسه مستعد روانگرایی</VernacularTitle>
			<FirstPage>63</FirstPage>
			<LastPage>75</LastPage>
			<ELocationID EIdType="pii">240275</ELocationID>
			
			
			<Language>FA</Language>
<AuthorList>
<Author>
					<FirstName>محمدعلی</FirstName>
					<LastName>مرادی</LastName>
<Affiliation>پژوهشکده مهندسی ژئوتکنیک، پژوهشگاه بین‌المللی زلزله‌شناسی و مهندسی زلزله</Affiliation>

</Author>
<Author>
					<FirstName>یاسر</FirstName>
					<LastName>جعفریان</LastName>
<Affiliation>پژوهشکده مهندسی ژئوتکنیک، پژوهشگاه بین‌المللی زلزله‌شناسی و مهندسی زلزله</Affiliation>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2016</Year>
					<Month>02</Month>
					<Day>13</Day>
				</PubDate>
			</History>
		<Abstract>In this study, the role of input motion characteristics on the amount of residual settlement of shallow foundations relied on liquefiable soil is investigated. First, two-dimensional numerical model is created using finite difference software FLAC-2D, and the UBCSAND constitutive model. After verification of the numerical model with the results of a centrifuge test, behavior of foundation is investigated under different earthquake loadings. To evaluate the effect of the input motion characteristics on foundation settlement, three records from Irpinia 1980, Northridge 1994, and Landers 1992 earthquakes are used. The frequency contents of these records are considerably different. These records are scaled to five levels of PGA (including 0.05g, 0.1g, 0.2g, 0.3g, 0.45g) to be used in the analyses. The results of the analyses demonstrate that the amounts of foundation settlement for the same PGA in three records are considerably different. Therefore, the use of PGA alone might be insufficient to predict the amount of foundation settlements. This fact is shown in Figure (1a). Figure (1b) illustrates the amounts of foundation settlement against the mean period of records at different PGA levels. It is observed that the mean period of records which indicates their frequency content, has a significant influence on the values of foundation settlements.</Abstract>
			<OtherAbstract Language="FA">وقوع پدیده روانگرایی در زلزله‌های مخرب گذشته،باعث بروز خسارت‌هایی به سازه‌ها شده است. در این میان، نشست‌های ماندگار سازه‌های مستقر بر پی‌های سطحی که بر خاک‎های روانگرا بنا شده بودند، خسارت‌های چشمگیری را به همراه داشته است. تحقیقات زیادی به‌منظور ارزیابی مقادیر نشست پی‌های سطحی بر خاک‌های روانگرا، بررسی پارامترهای تأثیرگذار و ارائه راهکارهایی جهت مقابله با آن انجام شده است. یکی از تأثیرگذارترین پارامترها، مشخصات زلزله ورودی می‌باشد که کمتر مورد بررسی قرار گرفته و معمولاً اثر زلزله ورودی را با شتاب بیشینه آن لحاظ می‌کنند. در این تحقیق، به بررسی اثر مشخصات زلزله ورودی با استفاده از مدلسازی عددی پرداخته شده است. برای این منظور، ابتدا مدل عددی ساخته شده با نرم‌افزار تفاضل محدود FLAC، با نتایج یک آزمایش سانتریفیوژ، صحت‌سنجی شده و بعد از آن، نشست سازه مستقر بر خاک روانگرا تحت بارگذاری‌های مختلف بررسی می‌شود. نتایج این تحقیق نشان می‌دهند که پارامتر شتاب بیشینه زلزله، به تنهایی نمی‌تواند اثر زلزله ورودی را در نظر بگیرد و تأثیر پارامترهای نشان‌دهنده محتوای فرکانسی زلزله مانند پریود میانگین، قابل توجه است. در مقابل، پارامترهایی که بر حسب سرعت حرکت زمین هستند، نظیر سرعت بیشینه زلزله ورودی، به تنهایی همبستگی بسیار خوبی با نشست پی‌های سطحی مستقر بر خاک مستعد روانگرایی دارند.</OtherAbstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">روانگرایی</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">نشست پی</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">پارامترهای موج</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">مدلسازی عددی</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">فشار منفذی اضافی</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://www.bese.ir/article_240275_b351546f98776abd3962e7bae0f2ce05.pdf</ArchiveCopySource>
</Article>

<Article>
<Journal>
				<PublisherName>پژوهشگاه  بین المللی زلزله شناسی و مهندسی زلزله</PublisherName>
				<JournalTitle>فصلنامه علوم و مهندسی زلزله</JournalTitle>
				<Issn>2476-6097</Issn>
				<Volume>2</Volume>
				<Issue>3</Issue>
				<PubDate PubStatus="epublish">
					<Year>2015</Year>
					<Month>09</Month>
					<Day>23</Day>
				</PubDate>
			</Journal>
<ArticleTitle>Influence of Masonry Infills with and without Opening on Progressive Collapse of Buildings (A Case Study: San Diego Hotel)</ArticleTitle>
<VernacularTitle>اثر میانقاب آجری با و بدون بازشو بر خرابی پیش‌رونده‌ی ساختمان (مطالعه‌ی موردی: هتل سان‌دیاگو)</VernacularTitle>
			<FirstPage>77</FirstPage>
			<LastPage>88</LastPage>
			<ELocationID EIdType="pii">240276</ELocationID>
			
			
			<Language>FA</Language>
<AuthorList>
<Author>
					<FirstName>مجید</FirstName>
					<LastName>محمدی</LastName>
<Affiliation>پژوهشکده مهندسی سازه، پژوهشگاه بین‌المللی زلزله‌شناسی و مهندسی زلزله</Affiliation>

</Author>
<Author>
					<FirstName>ناهید</FirstName>
					<LastName>اینانلو</LastName>
<Affiliation>پژوهشگاه بین‌المللی زلزله‌شناسی و مهندسی زلزله</Affiliation>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2016</Year>
					<Month>02</Month>
					<Day>13</Day>
				</PubDate>
			</History>
		<Abstract>Progressive collapse starts with local destruction of a few elements of structures, which extends into a significant part of the building. Regular buildings are designed for dead, live, wind, earthquake and other normal loads. Nevertheless, there are other possible risks and loads, including firing, vehicle collision, gas explosion, design or construction error, bomb blast, etc. These risks occur very rarely, but they may cause a catastrophic collapse; therefore, for very important structures, they should be considered in the designing phase [1]. Infills have a considerable improvement in the stiffness and the strength of the frame. Therefore, their influences on progressive collapse of buildings should be considered. Considering such elements in structural modelling is very complicated, that’s why many standards and codes ignore their local and global effects and just consider their effects in decreasing the building natural period of vibration [2]. However, they are considered in rehabilitation projects and should be considered in progressive collapse analyses [3-4]. Many methods have already been proposed to model solid infills in the structure; the most common approach is modelling by diagonal struts [4, 5]. For infills with openings, there is not a verified approach for the modelling. This study is to propose a method for modelling infills with and without opening and investigating their effects on progressive collapse of buildings. Perforated infills are modelled by the equivalent struts, considering the influence of the opening as a reduction factor for the width of the strut, verified in previous studies [6]. The proposed model is verified by the results of an experimental study on San Diego Hotel, obtained by Sasani [3]. The plan of the hotel is shown in Figure (1). The hotel had reinforced concrete structure and was destructed by explosion in two columns (A2 and A3 in Figure 1) of the first story.</Abstract>
			<OtherAbstract Language="FA">در سال‌های اخیر به دلیل وقوع حملات تروریستی، بررسی پتانسیل خرابی پیشرونده در سازه‌های مهم موجود یا در دست احداث ضروری به نظر می‌رسد. خرابی پیشرونده وضعیتی است که در آن بروز خرابی موضعی در یک عضو سازه‌ای، منجر به شکست اعضای مجاور و نهایتاً خرابی کل سازه می‌گردد. سازه‌های مهم که ممکن است در معرض خرابی پیشرونده قرار بگیرند باید به گونه‌ای طراحی شوند که اگر هر یک از اجزای آنها از بین بروند، مسیرهای جایگزین برای انتقال بار از آن عضو موجود باشند و اعضای باربر اطراف عضو محذوف، بدون وقوع فروریزش کلی، ظرفیت اضافی جهت تحمل نیروی آن را داشته باشند. ازآنجایی‌که وجود میانقاب موجب افزایش سختی و مقاومت سازه می‌شود، درنظرگیری اثر آن بر خرابی پیشرونده ضروری است. هدف از این تحقیق، ارائه‌ی روشی مناسب برای مدلسازی میانقاب با و بدون بازشو و بررسی اثر آن بر خرابی پیشرونده می‌باشد. مدل سه بعدی سازه‌ی بتنی در نرم‌افزار اپنسیس (Opensees)، در دو حالت با و بدون میانقاب، ایجاد شده و پس از تحلیل با هم مقایسه شده‌اند. مدل پیشنهادی با نتایج آزمایش موجود در ادبیات فنی، صحت‌سنجی شده است. نتایج تحلیل دینامیکی غیرخطی نشان داد که با در نظرگرفتن اثر میانقاب، تغییر مکان قائم سازه‌ی تحت حذف ستون، بسیار کمتر از حالتی است که از اثر میانقاب صرفنظر شده باشد.</OtherAbstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">خرابی پیشرونده</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">میانقاب</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">بازشو</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">تحلیل دینامیکی</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://www.bese.ir/article_240276_39d0720c17c4c94bfae1480fa3f3e075.pdf</ArchiveCopySource>
</Article>

<Article>
<Journal>
				<PublisherName>پژوهشگاه  بین المللی زلزله شناسی و مهندسی زلزله</PublisherName>
				<JournalTitle>فصلنامه علوم و مهندسی زلزله</JournalTitle>
				<Issn>2476-6097</Issn>
				<Volume>2</Volume>
				<Issue>3</Issue>
				<PubDate PubStatus="epublish">
					<Year>2015</Year>
					<Month>09</Month>
					<Day>23</Day>
				</PubDate>
			</Journal>
<ArticleTitle>Using Base Isolation Method to Mitigate  the Seismic Response of Liquefied Natural Gas</ArticleTitle>
<VernacularTitle>استفاده از جداسازها در کاهش پاسخ لرزه‌ای مخازن ذخیره‌ی گاز مایع (یادداشت تحقیقی)</VernacularTitle>
			<FirstPage>89</FirstPage>
			<LastPage>100</LastPage>
			<ELocationID EIdType="pii">240277</ELocationID>
			
			
			<Language>FA</Language>
<AuthorList>
<Author>
					<FirstName>محمدعلی</FirstName>
					<LastName>گودرزی</LastName>
<Affiliation>پژوهشکده مهندسی سازه، پژوهشگاه بین‌المللی زلزله‌شناسی و مهندسی زلزله</Affiliation>

</Author>
<Author>
					<FirstName>پرویز</FirstName>
					<LastName>رفعتی</LastName>
<Affiliation>دانشگاه جامع امام حسین (ع)</Affiliation>

</Author>
<Author>
					<FirstName>سهیل</FirstName>
					<LastName>رستمکلایی</LastName>
<Affiliation>پژوهشگاه بین‌المللی زلزله‌شناسی و مهندسی زلزله</Affiliation>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2016</Year>
					<Month>02</Month>
					<Day>13</Day>
				</PubDate>
			</History>
		<Abstract>During the last 20 years, part of the research work has focused on the seismic analysis of Liquefied Natural Gas (LNG) tanks, due mainly to (1) the increasing number of LNG tanks constructed in seismically active regions, resulting from the adoption of LNG as an environmentally friendly fossil fuel, and (2) the catastrophic environmental impact, associated with a potential local or total failure of such tanks, caused by the earthquake motion. Seismic isolation is a well-known method to mitigate the earthquake effects on the structures by increasing their fundamental natural periods at the expense of larger displacements in the structural system. In this study, the seismic response of isolated and fixed base vertical, cylindrical, liquid storage tanks is investigated using a numerical model, taking into account the fluid-structure interaction effects. The numerical model is validated by the comparison of its results with the experimental measurements of small-scale tank under harmonic and seismic excitations. The comparison reveals that the use of the considered model provides enough accuracy for evaluating the seismic behavior of nonlinear isolated and non-isolated tanks. Three vertical, cylindrical tanks with different ratios of height to radius (H/R=2.6, 1.0 and 0.3 as the representatives of slender, medium and broad tanks) are analyzed and the results of response-history analysis, including base shear, overturning moment and free surface displacement are reported for isolated and non-isolated tanks. The isolated tanks are equipped with lead rubber bearings isolators, and the bearings are modeled by using a non-linear spring in numerical model. Long period ground motion is the main parameter that can significantly affect the seismic response of isolated tank. It is observed that the seismic isolation of liquid storage tanks is quite effective and the response of isolated tanks is significantly influenced by the system parameters such as their fundamental frequencies and the aspect ratio of the tanks. The average reductions of base shear forces of isolated tanks are 71%, 70% and 50% for broad, medium and slender isolated tanks. It seems that the effectiveness of base isolation system to mitigate the base shear force is not significantly affected by changing of tank aspect ratio. In terms of overturning moment, the average reductions of the order of 71%, 69% and 47% for broad, medium and slender tanks is obtained due to applying of isolation system. Therefore, overturning moment is considerably mitigated by the reduction of the tank aspect ratio. The effectiveness of base isolation considerably reduces for exerted earthquake records including long period motion. Especially for slender tanks, base isolation may even increase the overturning moment. However, the base isolation does not significantly affect the surface wave height, and even it can cause adverse effects on the free surface sloshing motion. The results of free surface displacement for both isolated and non-isolated tanks have quite similar trends for considered tanks. The errors between the maximum sloshing wave height of fixed base and isolated tank are less than 8% for most of the considered cases. Even, the sloshing height is slightly amplified in some cases. Therefore, the base isolation system can cause adverse effects on the free surface sloshing motion. &lt;br /&gt;It can be concluded that the effectiveness of the base isolation method is very sensitive to the physical and geometrical parameters of the considered tanks. This suggests that a careful selection of isolators with a certain limit on the mechanical properties of the isolators is required for the optimal seismic isolation design of liquid storage tanks.</Abstract>
			<OtherAbstract Language="FA">با مطرح شدن طرح ذخیره‌سازی گاز در کشور، ساخت مخازن ذخیره گاز طبیعی مایع، در اولویت قرار گرفته است. امنیت لرزه‌خیزی این سازه‌ها نیز با توجه به خطرهای جبران ناپذیری که ممکن است در پی داشته باشد،باید به طور جدی مد نظر قرار گیرد. وجود کف بتنی قوی، امکان استفاده از سیستم‌های جداساز لرزه‌ای را به عنوان یکی از راهکارهای مؤثر در کاهش پاسخ لرزه‌ای این مخازن فراهم می‌کند. در این مطالعه، میزان اثربخشی جداسازها در بهبود رفتار دینامیکی مخازن ذخیره مایع در هنگام اعمال بارهای لرزه‌ای بررسی شده است. در این راستا،از شبیه‌سازی رایانه‌ای برای پیش‌بینی رفتار دینامیکی سیال و سازه مخزن استفاده شده است. ابتدا مدل عددی پیشنهادی با استفاده از نتایج آزمایشگاهی راستی‌آزمایی شده و پس از اطمینان از صحت عملکرد مدل عددی، از آن برای انجام مطالعات پارامتری بر روی مخازن واقعی گاز مایع استفاده شده است. پاسخ دینامیکی مخازن ذخیره‌ی گاز مایع در هنگام اعمال بارهای دینامیکی مختلف بررسی شده و میزان اثربخشی مثبت جداسازهای لرزه‌ای مورد بحث قرار گرفته است. نتایج مطالعات پارامتری بیان‌کننده‌ی کاهش قابل توجه پاسخ لرزه‌ای مخازن گاز مایع مجهز به جداسازها است؛ اما در عین حال، ارتفاع امواج سطحی، در دامنه‌ی معمول مخازن کاهش قابل ملاحظه‌ای در اثر جداسازها ندارد. </OtherAbstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">جداسازهای لرزه‌ای</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">مخازن ذخیره‌ی گاز مایع</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">تحلیل دینامیکی مخازن</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">مطالعات عددی</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://www.bese.ir/article_240277_2b6496e70dc43ffe92f09baffd150860.pdf</ArchiveCopySource>
</Article>
</ArticleSet>
