Comparison of Viscous and Hysteresis Dampers in Reducing the Seismic Vulnerability of Resistant Steel Buildings Based on the Division of the Building’s Structure into Inner and Outer Parts Having Dynamic Interaction

Document Type : Articles

Authors

1 Department of Civil Engineering, Arak Branch, Islamic Azad University, Arak, Iran

2 Structural Engineering Research Center, International Institute of Earthquake Engineering and Seismology (IIEES), Tehran, Iran

Abstract

In order to avoid the adverse consequences of building design based on the conventional regulations, such as the necessity of evacuation of thousands of heavily-damaged buildings and their demolishment and reconstruction, the design of the structure in such a way to be repairable even after a major earthquake is a desired alternative design method. In this regard, the authors of the paper recently proposed dividing the building’s structure into two parts, inner and outer, with different periods, and using hysteresis dampers with suitable properties between them for energy dissipation. In the present study, the use of viscous dampers between the two parts of the structure for energy dissipation has been studied and the optimal locations and damping coefficient of the dampers have been determined. For this purpose, first, by dividing a 5-storey building into two sections and by using viscous dampers at the roof level, formulating the equations of motion and coding them in MATLAB platform, the appropriate damping coefficient of the viscous dampers was obtained. The results showed that by choosing the proper damping values, the system could absorb high amount of energy and significantly reduce the drift of the building stories. Then, three 5-, 8- and 11-story steel braced-frames buildings were designed using ETABS software and were divided into inner and outer parts, and modeled for seismic response analyses in PERFORM-3D software. Based on these analyses, performances of viscous dampers with appropriate damping coefficient and hysteresis dampers with appropriate stiffness and strength were compared. Results show that when viscous dampers with appropriate damping coefficient are used, the maximum story drift will be reduced by approximately 35% in the outer structure and approximately 50% in the inner structure relative to the integrated original structure. However, if the hysteresis dampers are used with the proper stiffness and strength, the maximum story drift relative to the integrated original structure will be reduced by approximately 20% in the outer structure and 65% in the inner structure.

Keywords


  1. Ziyaiefar, M. (2006) Vertical seismic isolation method in steel structures against earthquake. 6th International Conference on Seismology and Earthquake Engineering, International Institute of Seismology and Earthquake Engineering, pp. 1611-1620.
  2. Hejazi, F., Dalili, M. (2010) Coupling Parallel Buildings by Supplemental Viscous Damper Device. Proceedings of the International Conference on Computing in Civil and Building Engineering, pp. 361-370.
  3. Wijaya, M., Yamao, T. (2013) Seismic Performance Investigation of the Folded Cantilever Shear Structure. International Journal of Civil Engineering and Technology, pp. 145-153.
  4. Abdelraheem Farghaly, A. (2014) Optimization of Viscous Dampers with the Influence of Soil Structure Interaction on Response of Two Adjacent Buildings under seismic load. IOSR Journal of Engineering, pp. 18-27.
  5. Annapurna, V., Vankudre, S. (2014) Vibration Control of Adjacent Buildings Connected with Selected Types of Dampers, International Journal of Engineering Research & Technology (IJERT), pp. 1431-1436.
  6. Jamshidi, J., Hosseini, M. (2015) Dividing the building structure into two parts with dynamic interaction. 2nd International Conference on Earthquake Resistant City”, pp. 352-360.
  7. Bougteb, Y., Ray, T. (2018) Choice between series and parallel connections of hysteretic system and viscous damper for seismic protection of structures. Journal of Earthquake Engineering & Structural Dynamics, pp. 352-360.
  8. Taheri, A., Hosseini, M. and Moghadam, A.S. (2018) Creation of innovative earthquake resistant steel buildings by dividing the structure into inner and outer parts having interaction by hysteretic dampers. JVE International Ltd. Journal of Vibroengineering, pp. 477-493.
  9. Taheri, A. (2017) Dividing the Building’s Skeleton into Two Inner and Outer Interactive Parts and Using Yielding Dampers between them for Seismic Response Reduction. Ph.D. Dissertation submitted to Dept. of Civil Eng., Arak Branch of the Islamic Azad University, Arak, Iran.
  10. Iranian Code Of Practice For Seismic Resistant Design Of Buildings (2015) Standard No. 2800 4th edition.
  11. Federal Emergency Management Agency (2006) Pre-standard and Commentary for the Seismic Rehabilitation of Buildings, FEMA-356.
  12. American Building Society of Civil Engineers (2010) Minimum design loads for buildings and other structures.
  13. ATC-40, Applied Technology Council (1998) California Seismic Safety Commission.