Determining the Base Shear Relationship of Moment Steel Frame to Ensure Life Safety Level in Post-Earthquake Fire

Document Type : Research Article

Authors

1 Ph.D. of Structural Engineering, Malayer University, Malayer, Iran

2 Assistant Professor of Geotechnical Engineering Department of Civil Engineering, Faculty of Civil and Architecture Engineering, Malayer University, Malayer, Iran

3 Associate professor, Faculty of Engineering, Imam Khomeini International University, Qazvin, Iran

Abstract

Post-Earthquake Fire (PEF) is an incident that can lead to a crisis and can be more critical than the earthquake itself due to the problems of passing vehicles and providing aid and assistance to the residents after the earthquake, and it can cause a lot of human and financial losses. Despite the large history of post-earthquake fires, the design regulations do not take into consideration the simultaneous effect of fire load and earthquake. On the other hand, in design based on the performance of structures, structural members should be designed for a specific level of performance that depends on the importance of the structure, which in the event of a post-earthquake fire, the performance level of the structure can change .Structures that are designed according to the regulations for the level of life safety performance may deviate from the desired level in the event of a fire after an earthquake. In this research, Post-Earthquake Fire was modeled in a moment steel frame. In this modeling, various levels of ground motion intensity and several time intervals were considered to extinguish the fire in the event of a post-earthquake fire. Three-story moment steel frame structures were modeled using OpenSEES software and studied to the performance level of life safety. Considering 44 different accelerograms, first, a scale of these accelerograms was applied to the structure. Then, assuming 60 seconds of free vibration to damping of the structure, the thermal load was applied to the members exposed to heat under the nine-point heat gradient, taking into account the ISO834 standard fire curve. Considering the maximum relative displacement between floors of 2.5% for the safety performance level, the quasi-acceleration spectrum component in the period of the first mode of the structure (Sa(T1)) was determined for this maximum relative displacement between floors under earthquake alone. Then, for different durations of post-earthquake fires, the maximum relative displacement between the floors under post-earthquake fires was determined and  Sa(T1) of a scale of the accelerogram applied was determined so that the structure under earthquake alone can have a maximum relative displacement between floors equal to the maximum displacement between floors under post-earthquake fire, and finally with this ratio Sa(T1) to Sa(T1) of the accelerogram scale, which had produced a maximum relative displacement of 2.5% between floors in the structure, a coefficient was obtained to modify the base shear to provide the performance level of life safety for various durations of post-earthquake fire.

Keywords

Main Subjects


  1. Faggiano, B., De Gregorio, D. and Mazzolani, F. (2010) Assessment of the robustness of structures subjected to fire following earthquake through a performance-based approach. Int. Conference Urban Habitat Constructions under Catastrophic Events (COST C26 Action), Naples, Italy, 207-212.
  2. Faggiano, B. and Mazzolani, F. (2011) Fire after earthquake robustness evaluation and design: Application to steel structures. Steel Construction, 4(3), 183-187.
  3. Hibbitt, Karlsson and Sorensen, Inc. (2004) ABAQUS User’s Manual Version 6.5, Pawtucket, RI.
  4. Prestandard, F. (2000) Commentary for the seismic rehabilitation of buildings (FEMA356). Washington, DC: Federal Emergency Management Agency, 7.
  5. Hietaniemi, J. and Mikkola, E. (2010) Design Fires for Fire Safety Engineering. Technical Research Centre, Helsinki, Finland.
  6. Behnam, B. and Ronagh, H.R. (2014) Behavior of moment-resisting tall steel structures exposed to a vertically traveling post-earthquake fire. The Structural Design of Tall and Special Buildings, 23(14), 1083-1096.
  7. Memari, M., Mahmoud, H. and Ellingwood, B. (2014) Post-earthquake fire performance of moment resisting frames with reduced beam section connections. Journal of Constructional Steel Research, 103, 215-229.
  8. Khorasani, N.E., Garlock, M.E. and Quiel, S.E. (2015) Modeling steel structures in OpenSees: Enhancements for fire and multi-hazard probabilistic analyses. Computers & Structures, 157, 218-231.
  9. Mazzoni, S., McKenna, F., Scott, M.H. and Fenves, G.L. (2006) OpenSees Command Language Manual. Pacific Earthquake Engineering Research (PEER) Center, 264.
  10. Franssen, J.-M., Kodur, V. and Mason, J. (2000) User’s Manual for SAFIR-2001: A Computer Program for Analysis of Structures Submitted to the Fire. University of Liege, Belgium.
  11. Behnam, B. (2016) Structural response of vertically irregular tall moment-resisting steel frames under pre- and post-earthquake fire. The Structural Design of Tall and Special Buildings, 25(12), 543-557.
  12. Behnam, B. (2018) Failure sensitivity analysis of tall moment-resisting structures under natural fires. International Journal of Civil Engineering, 16(12), 1771-1780.
  13. Moradi, M., Tavakoli, H. and Abdollahzadeh, G. (2019) Probabilistic assessment of failure time in steel frame subjected to fire load under progressive collapses scenario. Engineering Failure Analysis, 102, 136-147.
  14. Alasiri, M.R., Chicchi, R., & Varma, A.H. (2021) Post-earthquake fire behavior and performance-based fire design of steel moment frameJournal of Constructional Steel Research177, 106442.
  15. Venture, S.J. (1994) Proceedings of the Invitational Workshop on Steel Seismic Issues. Report No. SAC 94-01, Los Angeles, CA.
  16. S.S.C. UBC )1994( Edition NEHRP Recommen-ded Provisions for Seismic Regulations for New Buildings, Federal Emergency Management Agency.
  17. Krawinkler (2000) Estate of art report on systems performance of moment resisting steel frames subject to earthquake ground shaking. FEMA 355c.
  18. Lignos, D.G. and Krawinkler, H. (2010) Deterioration modeling of steel components in support of collapse prediction of steel moment frames under earthquake loading. Journal of Structural Engineering, 137(11), 1291-1302.
  19. Ancheta, T., Darragh, R., Stewart, J., Seyhan, E., Silva, W., Chiou, B., Wooddell, K., Graves, R., KO-TTKE, A., Boore, D. (2013) PEER NGA-West2 Database. PEER Report 2013/03, Pacific Earthquake Engineering Research Center, University of California, Berkeley.
  20. FEMA, P. (2009) Quantification of Building Seismic Performance Factors, ed: Washington, DC.
  21. ISO (1999) ISO 834: Fire Resistance Tests-Elements of Building Construction. International Organization for Standardization, Geneva, Switzerland.
  22. ASTM (2006) Standard Test Methods for Determining Effects of Large Hydrocarbon Pool Fires on Structural Members and Assemblies, ASTM E1529-06.
  23. ASCE (2006) Minimum Design Loads for Buildings and other Structures, SEI/ASCE 7–05. American Society of Civil Engineers, Reston, Virginia.
  24. Tanaka, T. (1998) Performance-based fire safety design of a high-rise office building. Proceedings of Pacific Rim Conference and Second International Conference on Performance-Based Codes and Fire Safety Design Meth.
  25. Moradi, M., Tavakoli, H. and Abdollahzadeh, G. (2020) Sensitivity analysis of the failure time of reinforcement concrete frame under postearthquake fire loading. Structural Concrete, 21(2), 625-641.
  26. Ghojel, J.I. and Wong, M. (2005) Three-sided heating of I-beams in composite construction exposed to fire. Journal of Constructional Steel Research, 61(6), 834-844.
  27. Quiel, S.E. and Garlock, M.E. (2010) Closed-form prediction of the thermal and structural response of a perimeter column in a fire. The Open Con-struction and Building Technology Journal, 4(1).
  28. Lewis, K.R. (2000) Fire Design of Steel Members.
  29. Behnam, B. and Ronagh, H.R. (2013) A post-earthquake fire factor to improve the fire resistance of damaged ordinary reinforced concrete structures. Journal of Structural Fire Engineering, 4(4), 207-226.